EXPLOSION-PROOF ELECTROMAGNETIC PILOT MAINTENANCE INSTRUCTIONS

Nadi solenoid valves maintenance can be made with the following tools without disassembling the solenoid valve from the pipes.

  TOOLS

1
 Solenoid housing security clip extration tool (Cod. Art. KM/3062)

2
 Flat screwdriver (max. 3x1)

3
 Special fixed core wrench (Cod. Art. KM/2621)

4
 Fixed core wrench lever-pin ( 8 mm dia.)

5
 Setscrew wrench n. 2

 6
 Wrench n.2


Operation n. 1

Be sure to have been switched off the power-supply before to start with the following operations

Unloose the security dowel using a n.2 setscrew wrench, turning anticlockwise.



Operation n. 2

Unscrew the solenoid housing threaded cap turning anticlockwise.




Operation n. 3



Insert the clip extraction tools in the hole of the solenoid housing security clip and pull until clip is extracted.



Operation n. 4

Unloose the terminal board screw and pull-up the two power-supply wires.

It is not necessary to unscrew the internal ground connecting wire.



Operation n. 5



 If present, unloose the exagon nut with a n. 19 wrench turning anticlockwise. Unscrew completely the exagon nut by hand.



Operation n. 6



If operation n. 5 has been made made, extract carefully the o-ring.




Operation n. 7



Pull up the solenoid housing until completely extracted from the fixed core of the solenoid valve.



Operazione n. 8


Extract the coil from the housing, through the threaded hole, rounding it light.



 Replace the coil and reassemble the pilot stepping back through the operation.